Pressure measurement amplifier DMV 622
with output 0-10V/0-20mA
Disponible
Descripción del producto
Pressure measurement amplifier DMV 622
for DMS pressure transducers housing for front panel installation 96 x 96 x 148 mm - digital display
- 2 limit values to be adjusted by code switch (0 - 999 bar)
- self-holding of the limit values optional
- analog output 0 - 20 mA/0 - 10 V
- adjustable sensitivity 1; 2 and 3, 3 mV/V
- measuring ranges 0 - 50 up to 0 - 999 bar
- calibration 80 %
- Optionally with/without protection against breaking of transducer. (Please indicate when ordering) - Supply 110/ 220 V, 50/ 60 Hz optional.